The inputs a designer uses to size central water heating for apartments, and why the old nameplate is not one of them. For owners, managers and their engineers.
Commercial water heater sizing for an apartment building comes down to three questions: how much hot water residents use at the busiest time, how much the plant stores versus how fast it reheats, and how much heat the recirculation loop loses.
This guide explains each input. It gives no sizing numbers: those come from a design calculation for your building, which the assessment provides.
Designers use published demand methods rather than rules of thumb. The ASHRAE Handbook (HVAC Applications, Service Water Heating chapter) is the common reference for gas plants. Central heat pump systems have their own approaches. One example is the Ecosizer, a free educational tool built by Ecotope, with funding from SCE and SMUD, for sizing central heat pump water heater systems in multifamily buildings.
Where possible, measured data beats any method. A few weeks of flow and temperature logging shows how the building actually uses hot water.
Unit count is a start, not the answer. Designers also look at:
A plant can meet a peak by storing a lot of hot water, by reheating quickly, or by a mix. More storage means smaller heaters but more space and tank cost. Faster recovery means larger heaters and gas or electrical capacity, but less storage.
Gas plants often lean on recovery. Heat pump plants usually lean on storage.
The recirculation loop keeps hot water close to every apartment, and it loses heat all day. That loss is part of the load. Pipe length, insulation, return temperature and pump control all change it.
Fixing a poorly insulated or badly balanced loop can reduce the plant size needed, so the survey checks it.
See central heat pump water heaters for equipment and siting.
This shows the process, not the result. The numbers depend on the building.
Bring in a mechanical engineer or design-build contractor when the plant serves many units, when you are converting fuel, when the electrical service may change, or when the permit requires stamped drawings. For a like-for-like swap in a small building, a contractor's sizing check may be enough.
It depends on peak demand, the storage and recovery balance, and recirculation losses. Two buildings with the same unit count can need different plants if occupancy, fixtures or piping differ. A designer calculates it for your building.
Not reliably. The old plant may have been oversized or undersized, or sized for a building that has since changed. Use it as a data point alongside complaint history and, ideally, measured use.
Yes. Heat pumps recover more slowly than gas burners, so central heat pump systems usually rely on more storage, and recirculation losses are often handled by a separate tank. Use a method built for heat pumps.
Equipment types, storage, siting and electrical readiness for a central plant.
Replacing central or multi-unit water heaters in an occupied building.
The three ways apartment buildings make hot water, and how to choose.
Send the building details once. Qualified requests go to a California contractor partner for a free, no-obligation assessment and quote.
The assessment and quote are free, with no obligation. Tell us about the building and the hot water equipment that serves it. An uncertain equipment age is fine.
This form is not an emergency dispatch service. If hot water has stopped, use the building's existing maintenance contacts.